6.5 MODULE 5 - T OTALIZER (I NTEGRATOR ) P ARAMETERS ( ????? )
5-tOt
PAR
PARAMETER MENU
Pro
dECPt
Totalizer
Decimal Point
tbASE
Totalizer
Time Base
SCFAC
Totalizer
Scale Factor
Locut
Totalizer Low
Cut Value
P-UP
Totalizer Power
Up Reset
?
? ?????
Factor Factor Factor
The totalizer accumulates (integrates) the Input Display value using one of
two modes. The first is using a time base. This can be used to compute a time-
temperature product. The second is through a user input or function key
programmed for Batch (one time add on demand). This can be used to provide
a readout of temperature integration, useful in curing and sterilization
applications. If the Totalizer is not needed, its display can be locked-out and this
module can be skipped during programming.
TOTALIZER DECIMAL POINT*
????? ?
? ??? ???? ????? ??????
????
For most applications, this matches the Input Display Decimal Point
( ????? ). If a different location is desired, refer to Totalizer Scale Factor.
TOTALIZER TIME BASE
????? ? ??? - seconds (÷ 1) ???? - hours(÷3600)
? ? ?? ? ?? - minutes (÷ 60) ??? - days (÷ 86400)
This is the time base used in Totalizer accumulations. If the Totalizer is being
accumulated through a user input programmed for Batch, then this parameter
does not apply.
TOTALIZER SCALE FACTOR*
????? ?
????? to ??????
For most applications, the Totalizer reflects the same decimal point location
and engineering units as the Input Display. In these cases, the Totalizer Scale
Factor is 1.000. The Totalizer Scale Factor can be used to scale the Totalizer to
a different value than the Input Display. Common possibilities are:
1. Changing decimal point location (example tenths to whole)
2. Average over a controlled time frame.
Details on calculating the scale factor are shown later.
If the Totalizer is being accumulated through a user input programmed for
Batch, then this parameter does not apply.
TOTALIZER LOW CUT VALUE*
????? ? ?????? to ?????
? ???????
A low cut value disables Totalizer when the Input Display value falls below
the value programmed.
TOTALIZER HIGH ORDER DISPLAY
When the total exceeds 5 digits, the front panel annunciator TOT flashes. In
this case, the meter continues to totalize up to a 9 digit value. The high order 4
digits and the low order 5 digits of the total are displayed alternately. The letter
“ ? ” denotes the high order display. When the total exceeds a 9 digit value, the
Totalizer will show “E . . .” and will stop.
TOTALIZER BATCHING
The Totalizer Time Base and scale factor are overridden when a user input or
function key is programmed for store batch ( ??? ). In this mode, when the user
input or function key is activated, the Input Display reading is one time added
to the Totalizer (batch). The Totalizer retains a running sum of each batch
operation until the Totalizer is reset. This is useful in weighing operations, when
the value to be added is not based on time but after a filling event.
TOTALIZER USING TIME BASE
Totalizer accumulates as defined by:
Input Display x Totalizer Scale Factor
Totalizer Time Base
Where:
Input Display - the present input reading
Totalizer Scale Factor - 0.001 to 65.000
Totalizer Time Base - (the division factor of ????? )
Example: The input reading is at a constant rate of 10.0 gallons per minute. The
Totalizer is used to determine how many gallons in tenths has flowed.
Because the Input Display and Totalizer are both in tenths of gallons, the
Totalizer Scale Factor is 1. With gallons per minute, the Totalizer Time Base
is minutes (60). By placing these values in the equation, the Totalizer will
accumulate every second as follows:
10.0 x 1.000 = 0.1667 gallon accumulates each second
60
This results in:
10.0 gallons accumulates each minute
600.0 gallons accumulates each hour
TOTALIZER SCALE FACTOR CALCULATION EXAMPLES
1. When changing the Totalizer Decimal Point ( ????? ) location from the
Input Display Decimal Point ( ????? ), the required Totalizer Scale Factor is
multiplied by a power of ten.
Example:
Input ( ????? ) = 0 Input ( ????? ) = 0.0 Input ( ????? ) = 0.00
Totalizer Scale Totalizer Scale Totalizer Scale
????? ????? ?????
0.0 10 0.00 10 0.000 10
0 1 0.0 1 0.00 1
x10 0.1 0 0.1 0.0 0.1
x100 0.01 x10 0.01 0 0.01
x1000
0.001
x100
0.001
x10
0.001
? ?? Reset buffer
TOTALIZERPOWERUPRESET*
???? ? ?? Do not reset buffer
???
The Totalizer can be reset to zero on each meter power-up by setting this
parameter to reset.
* Factory Setting can be used without affecting basic start-up.
22
(x = Totalizer display is round by tens or hundreds)
2. To obtain an average reading within a controlled time frame, the selected
Totalizer Time Base is divided by the given time period expressed in the same
timing units.
Example: Average temperature per hour in a 4 hour period, the scale factor
would be 0.250. To achieve a controlled time frame, connect an external timer
to a user input programmed for ????? . The timer will control the start (reset)
and the stopping (hold) of the totalizer.
相关PDF资料
PB-1583-TF BOX ABS 4.37X3.12X2" BK 1=10PCS
PB-1583 BOX ABS 4.37X3.12X2" BK 1=10PCS
PBS-11273 BOX ABS 6.30" X 3.75" X 1.41" BK
PBS-11275 BOX ABS 6.30" X 3.75" X 1.41" BK
PBS-11294-G BOX 5.62" X 3.25" X 1.5" GRAY
PBS-11327-B BOX 5.62" X 3.25" X 1.5" BLACK
PBS-11532-B BOX 4.37" X 3.25" X 1.52" BLACK
PBS-12631AV2G SWITCH PUSHBUTTON SPDT 6A 125V
相关代理商/技术参数
PAXTM110 制造商:Red Lion Controls 功能描述:TIMER, FIELD UPGRADEABLE GREEN DC 制造商:Red Lion Controls 功能描述:DC TIMER FIELD GREEN
PAXUSB00 制造商:Red Lion Controls 功能描述:USB PROGRAMMING CARD FOR PAX SERIES 制造商:Red Lion Controls 功能描述:USB OPTION CARD
PAY23015A12 功能描述:硬公制连接器 LOCKING PIN ASSEMBLY RoHS:否 制造商:TE Connectivity / AMP 系列:Z-Pack 产品类型:Receptacles 排数:5 位置/触点数量:110 安装角:Right 端接类型:Pin 外壳材料:Polyester 触点材料:Phosphor Bronze 触点电镀:Gold 类型:
PAY23015A1A1 功能描述:硬公制连接器 GRIP FINGER RoHS:否 制造商:TE Connectivity / AMP 系列:Z-Pack 产品类型:Receptacles 排数:5 位置/触点数量:110 安装角:Right 端接类型:Pin 外壳材料:Polyester 触点材料:Phosphor Bronze 触点电镀:Gold 类型:
PAY245A10 功能描述:手工工具 HM2 CONTACT EXTR TOOL-LONG PINS RoHS:否 制造商:Molex 产品:Extraction Tools 类型: 描述/功能:Extraction tool
PAY245A106 功能描述:手工工具 RoHS:否 制造商:Molex 产品:Extraction Tools 类型: 描述/功能:Extraction tool
PAY245A11 功能描述:手工工具 HM2 CONTACT EXTR TOOL-SHORT PINS RoHS:否 制造商:Molex 产品:Extraction Tools 类型: 描述/功能:Extraction tool
PAY245A112 功能描述:手工工具 INSERT BLOCK RoHS:否 制造商:Molex 产品:Extraction Tools 类型: 描述/功能:Extraction tool